John Kim 1 boiler vs 3 boilers
13 November 2019 | 4 replies
I got quotes of $35,000, $40,000 and $35000.Cut out and remove the existing cast iron hot water boiler, both hot water heaters.Cut out and remove the existing 11/2"-21/2" supply and return heating mains that run from the mechanical room (back of the house) to the meter room (front of the house).Install 2- 9 port manifold stations in the mechanical for supplying heat to the cast iron radiators.Plumb the supply and return (home runs) 1/2" pex tubing for the cast iron radiators from the manifolds to the existing branch of risers in the basement ceiling.Pressure test all piping.Pipe new 11/4"x 50' gas piping from the meter room to the mechanical room.Pressure test gas piping.Install a HTP UFT 140 high efficient modulating condensing hot water boiler and a Turbomax 45 Reverse Indirect Tank (Buffer tank and Potable hot water) with near boiler piping and controls containing:The supply and return header piping from the UFT 140 boiler to the Turbomax 45 will be piped in a 2 pipe buffer tank configuration.Isolation drain and purge valves.Air and dirt magnet separators.High efficient ECM circulating pumps with isolation pump flanges.Hydronic expansion tank with support bracket.Back flow preventer and auto filer combo unit.Inline sediment and De-minerlized filter.Controls & Wiring:Low Water Cut Off.18- Manifold Actuators.Zone Control Box's.3-Thermostats with wireless sensors.Outdoor Sensor.Cold and Hot water potable water side:Isolation valves.Thermostatic mixing valve.Thermal expansion tank with support bracketPipe 3" Polypropylene and PVC flue and air intake piping from the boiler to the outside along with a thin low profile termination kit.Install a Condensate neutralizer pump and plumb the discharge tubing from the pump to the indirect stand pipe in the mechanical room.Pressure test all piping.Install and wire in all controls in the mechanical room.Power flush the system and remove any debris that is in the radiators and piping.Drain the water out of the entire system.Re-fill the entire heating system with De-mineralized water and power purge all the air out of the entire system.Set and adjust the flow meters on the manifolds as per radiators btu's output.Perform a combustion analysis on the boiler and make any adjustments if needed.
Matt Leonard Trumps New Tax Plan, Does it hurt RE Investors?
16 January 2018 | 69 replies
Agree, lowering rates puts more cash in circulation with the people.
Percy Matsunaga Legal zoom vs Attorney?
7 May 2016 | 9 replies
To piggy back on what @James Miller and @Scott Hildebrand already said; with how prevalent legal zoom is and how readily available these templates are in circulation, I would think it's fairly likely that the litigation guys have already combed through those bad boys and know how to poker every hole possible in their validity.Just an assumption, but definitely something I'd be mindful of. 
Zeb Walters Creative Solutions to Avoiding Property Registration
11 September 2022 | 12 replies
Now they're looking for moss on the roof, water heater strapping, two railings on stairways, tread depth, window egress, fans and circulation, legal bedroom size.
Joseph Weisenbloom Anyone use only minisplits to cool/heat an entire house?
6 February 2024 | 3 replies
How do I circulate conditioned air to hallways, bathrooms etc? 
Ray Hull The money multiplier method
20 October 2022 | 8 replies
There has been multiple threads on this forum about the benefit of using a maximum overfunded cash value permanent life insurance as the place where to circulate your cash flow.The Infinite Banking crowd only swear by Whole Life insurance; There are other options like Index Universal Life.In a few words, it's a long term play as the upfront fee make it a negative return until year 5~7 depending on the product.
Tim S. Investable areas between Seattle and Tacoma?
19 February 2020 | 43 replies
I don't know where he got this figure - mostly he was complaining about good farmland being taken out of circulation without including some sort provision for local ag.
Jaleh Mozafarian Beginner tax question
28 December 2023 | 8 replies
Hi Jaleh, These questions and concerns are best handled by a profession due to the sensitive and impactful nature of your decision circulating these issues.
Duke Giordano Tax attorney for LLC set up with real estate experience
12 October 2019 | 4 replies
There are several asset protection attorneys circulating on BP.
Luke Carl Driving myself nuts with Fridge selection
28 March 2020 | 14 replies
@Lucas CarlLive with 3" on each side and enjoy longer life from adequate circulation.